top of page

SOUNDPROOF CABINS

Industrial soundproofing cabins and noise protection structures offered by Zakład Budowy Urządzeń i Aparatury Naukowo-Doświadczalnej Sp. z o. o. are intended for persons operating devices and machines operating in conditions where noise exceeds the permissible values.

Soundproofing cabins are separate rooms with the required acoustic insulation. They fulfill the function of soundproofed rooms - protecting employees from noise. The solutions offered are the result of many years of experience of ZBUiAND Sp. z o. o. in the construction, delivery and assembly of structures that provide the user with the maximum possible comfort, both in terms of noise attenuationand functionality as well as aesthetics of the structure. Soundproofing cabins for service workers are used in rooms where the production process can be controlled from the cabin or it is possible for an employee to stay in the cabin temporarily; are used as controls and control rooms, rooms for technical supervision or social and rest rooms located in production halls with high noise levels.

The obtained certificate of compliance with the essential requirements contained in Annex II of Directive No. 94/9/EC (ATEX) allows the use of cabins in zones 21 and 22 of dust mixture explosion hazard, in zones 1 and 2 of explosion hazard combustible vapor gases  and in underground excavations of mines classified as "a", "b" and "c" methane explosion hazard and class A and B coal dust explosion hazard. The cabins also have a certificate authorizing the product to be marked with the B safety mark.

Slider-05.jpg
3.jpg
2.jpg
1.png

The soundproofing cabin is constructed in a segmented form and consists of wall, floor and ceiling elements. Thanks to the use of repeatable modules, it is possible  to adjust the dimensions of the cabin to the customer's needs. The design allows for easy and quick assembly. Cabin segments are multi-layer constructions filled with materials characterized by high acoustic insulation. The cabin is equipped tight windows and doors; Depending on the customer's needs, the doors and windows can be made in both hinged and sliding versions. The material of the outer walls is coated or stainless steel. Depending on the needs, the cabin can be placed on vibration isolators. The cabins are adapted for use in closed (roofed) rooms. The manufacturer makes an individual design of the cabin free of charge. The acoustic insulation of the cabin can range from 25 to 35 dB depending on customer requirements.

Industrial soundproofing cabins can be equipped with:

  • lighting installation,

  • ventilation and air-conditioning installation,

  • industrial television,

  • inspection door dismantled to facilitate access to the control cabinets in the cabin,

  • other additional devices according to the Customer's request, corresponding to local building conditions.

Cabins are made according to individual location conditions, as well as in typical sizes. Additional equipment is installed depending on the Customer's requirements. Elements of electrical additional equipment used for this purpose, such as: lighting fixtures, fans, heaters, air conditioners, CCTV (cameras, monitors) and others, meet the requirements resulting from the qualification of the room in which the cabin will be built. In explosion hazard zones, explosion-proof equipment is installed that meets the essential requirements set out in the regulations on products subject to conformity assessment.

puławy po montażu 020.jpg
IMG_5175.png
2010 012.jpg
02 (2).png
IMG_9629.png
DSCF6489.png

Industrial soundproofing cabins can be equipped with:

  • lighting installation,

  • ventilation and air conditioning installation,

  • closed-circuit television,

  • inspection door removable for easy access to control cabinets located in the cabin,

  • other additional equipment as requested by the customer corresponding to the local conditions of construction.

  Cabins are made according to individual location conditions, as well as in typical sizes. Additional equipment is installed according to the requirements of the Customer. The electrical auxiliary equipment used, such as light fixtures, fans, heaters, air conditioners, CCTV (cameras, monitors)
and others, meet the requirements arising from the qualification of the room in which the cabin will be built. In explosive atmospheres, equipment of explosion-proof construction that meets the essential requirements specified in the regulations on products subject to conformity assessment shall be installed.

01.JPG
02.JPG
01 (2).JPG
4.JPG
02 (3).jpg
031.JPG
08.JPG
20130702_085841.jpg
20151218_214236.jpg
21.JPG
011.JPG
20151218_214952.jpg
20151218_214426.jpg
20190523_142312.jpg
20161230_131244.jpg
20161230_131224.jpg
20190523_142605.jpg
20190917_153456.jpg
20190917_164510.jpg
Bez tytułu.jpg
20190523_164052.jpg
20190523_164244.jpg
DSC_0005.jpg
DSC_0180.JPG
DSC_2775.jpg
DSC_0053.JPG
DSC_0181.JPG
DSC_2780.jpg
DSCF5092.JPG
DSCF4100.JPG
DSC_2786 - Kopia.jpg
DSCF5028.JPG
DSCF4091.JPG
DSCF5037.JPG
DSCF6378.JPG
DSCF6489.jpg
DSCF6379.JPG
DSCF6397.JPG
DSCF6481.JPG
DSCF6507.JPG
DSCF7741.JPG
DSCF6956.JPG
IMG_0081.JPG
IMG_0630.JPG
IMG_0087.JPG
IMG_1643.JPG
IMG_1636.JPG
IMG_0636.JPG
IMG_1633.JPG
IMG_2603.jpg
IMG_2593.jpg
IMG_1628.JPG
IMG_2920.JPG
IMG_0672.JPG
IMG_5175.jpg
IMG_1657.JPG
IMG_5196.JPG
IMG_6975.JPG
IMG_5215.JPG
IMG_6793.JPG
IMG_5660.jpg
IMG_5216.JPG
IMG_5662.jpg
IMG_9629.JPG
IMG_9621.JPG
IMG_9629.png
IMG_9740.JPG
IMG-20191007-WA0002.jpg
IMG_9637.JPG
IMG_6976.JPG
IMG_9732.JPG
puławy po montażu 020.jpg
IMG-20191007-WA0004.jpg
P1100001.JPG
bottom of page